ANSI ISEA Z87-1:2020 pdf download
ANSI ISEA Z87-1:2020 pdf download.American National Standard for Occupational and Educational Personal Eye and Face Protection Devices.
ANSI ISEA Z87-1 sets forth criteria related to the requirements, testing, permanent marking, selection, care, and use of protectors to minimize the occurrence and severity or prevention of injuries from such hazards as impact, non-ionizing radiation and liquid splash exposures in occupational and educational environments including, but not limited to, machinery operations, material welding and cutting, chemical handling, and assembly operations. Certain hazardous exposures are not covered in this standard. These include, hut are not limited to: bloodhorne pathogens, X-rays, high-energy particulate radiation, microwaves, radio-frequency radiation, lasers, masers, and sports and recreation.
2.2 Purpose
ANSI ISEA Z87-1 provides minimum requirements for protectors including selection, use, and maintenance of these protectors as devices to minimize or prevent eye and face injuries.
2.3 Application
2.3.1 The requirements of ANSI ISEA Z87-1 apply to protectors when first placed in service.
2.3.2 Protectors bearing the permanent marking Z87 shall meet all applicable requirements of this standard in its entirety. All components of eye and face protectors shall comply with the requirements of this standard. Accessories installed by the manufacturer shall not cause the protector to fail the requirements of this standard. Manufacturers of components, aftermarket components, accessories and complete protectors shall ensure that all required tests have been performed to demonstrate conformance.
2.3.3 Compliance with this standard cannot always be assured when components are replaced or accessories are added. End users should exercise extreme care in the selection and installation of components to ensure compliance with ANSI ISEA Z87-1.
2.3.4 Non-compliant components shall not be used with ANSI/ISEA Z87.1-compliant components.
2.3.5 The protector manufacturer shall provide test results to the purchaser upon request.
2.3.6 Eye and face protectors complying with the requirements of this standard shall not preclude the devices from complying with other relevant standards, as applicable.
2.4 Interpretations
Requests for interpretations of ANSI ISEA Z87-1 shall he in writing and addressed to the secretariat (isea@safctycquipmcnt.org) of this accredited standard committee.
3. Definitions
For purposes of this standard, the following dellnitions shall apply:
accessory. An item that is added to a complete device that may or may not affect the performance of that complete device.
aftermarket component. A component that may or may not be manufactured by the complete device manufacturer and is not supplied with the original complete device.
astigmatism. A condition in a lens of a protector in which there is a difference in refractive power in one meridian from that in another meridian.
automatic darkening welding filter lens. A fIlter lens that automatically switches from a light state to a dark state in response to a change of light intensity.
bluclight transmittance TB. Transmittance of optical radiation weighted by its ability to cause photochemical damage to the retina is defined as.ANSI ISEA Z87-1 pdf download.